- purpose:
- Fill concave gaps in a specified direction for a
specified subsection of the input volume. To do
this for the transverse direction, a 3
3
(last_slice - first_slice + 1)
closing is performed on the volume. For sagittal, a 3
(last_slice - first_slice + 1)
3 closing is
performed. For coronal, a (last_slice - first_slice + 1)
3
closing is performed. In all cases, the
analysis is done between slices numbered from first_slice
to last_slice. A closing is an operation from
mathematical morphology [25,19].
- input:
- An 8-bit volume.
- output:
- An 8-bit volume.
- parameters:
- Default parameters menu is
direction = transverse
*
first slice = 1
*
last slice = 1
*
input from vol # = 0
*
copy output to vol # = 0
*
- comments:
-
- Note that the size of the gaps filled is determined by the total
number of slices to analyze. This is a little peculiar for
filling gaps in the transverse plane. Thus, to fill gaps of
width=5 in the transverse plane, you may have to repeat this
procedure a number of times on groups of 5 slices.
- This operation takes a moderate amount of computation time.